Single Phase Digital Ammeter SDA-91

SDA-91
Display Type 7 Segment LED Display
Display Configuration 4 Digits
Connection type 1 Phase 2 Wire (AC applications)
Measuring current range 50mA - 6A
Nominal current range(In) 1A or 5A
Overload 150% Un continuous
Short time over current 120 A for 1 sec
Size 96 x 96mm
Mounting Type Panel Mount
Specifications
Display Single row, 7 segments LED Display
Digits 4
Digit Height 0.56" (14.2mm)
Display Range 0 - 4960V
Mounting Panel
Weight 180 gms
Electrical Connection 1 Phase-2 wire
Input Type AC
Input Current Range 50mA - 5A
Continuous Max. Input Rating 6.2A
Overrange Indication “ Or” for input > 6.2A
Frequency 50 / 60Hz
Resolution 0.001, 0.01, 0.1, 1A (Depending upon
CT Primary)
Accuracy ±0.5% of CT primary
Input Burden 0.5 VA at 5A
Sampling Rate 3 samples / second
Dielectric withstand Voltage 2kV AC between auxiliary supply & measuring input
Rated Impulse withstand Voltage 3.5kV (1.2/50µS)
Auxiliary Supply 240V AC (±20%), 50 / 60Hz
110V AC (±20%),  60Hz
Power Consumption 5VA max
CT Primary / Shunt Setting 5, 10, 20, 30, 40, 50, 60, 75, 80, 100, 150, 200,
250, 300, 400, 500, 600, 800, 1000, 1200, 1500, 1600, 2000, 2500, 3000, 4000
C T Secondary 5A (Fixed)
Temperature Operating : -10° to 55°C Storage : -20° to 75°C
Humidity (non - condensing) Upto 95% RH