SINGLE PHASE POWER SUPPLY 12V, 14A

SPP1-12180
Input Voltage AC

115-230 V AC    

Output Voltage DC 12 V DC
Output Current 14A
 Input Data
Nominal Input Voltage (2 x Vac)
Manual select Input from 115 to 230
115 – 230 Vac
Input Voltage Range (Vac) 90 - 135 (115)
180 – 264    (230)
Inrush Current (Vn and In Load) I 2t 11A   5msec.
Frequency 47 – 63 Hz ±6%
Input Current  (115 – 230 Vac) 2.8 - 1.3A
Internal Fuse T 4 A
External Fuse (recommended) 10 A (MCBcurve B)
Output Data
Output Voltage (Vn)  Factory Setting ±3% 12 Vdc
Adjustment range (Vadj) 10 – 14 Vdc
Start up with Strong Load (capacitive load) ≤50.000µ F
Turn-On delay after applying mains voltage 1 sec. (max)
Rated Current at 12 V 40°C  (In) 14 A (permanent)
Rated Current at 12 V 50°C  (In) 12 A (permanent)
Rated Current at 12 V 60°C  (In) 10 A (permanent) 3 min.
Power Boost Current at 12 Vdc 60°C(In) In (60°C) x 1.5
Current max. Overload ≅        4Vdc (permanent) Imax=In60°Cx(1.8 - 2.2)
Current Short Circuit Icc Max 2 sec.: Hiccup mode
Permanent : Continuous Mode
20 A
Hold-up Time ( min. Vac)  12Vdc 5A T yp. 20 msec
Residual Ripple 80 mVpp
Efficiency 91 %
Over temperature Protection Yes. Shut-down output and automatic restart.
Short-circuit protection 1° Hiccup Mode
2° Continuous mode
3° Manual Reset
Dissipation power load max (W) 17
Over Load protection Yes
Over Voltage Output protection Yes (typ. 35 Vdc)
Parallel connection Yes
Power Good Contact rating (EN60947.4.1):
Max. DC1: 30 Vdc 1 A;
AC1: 60 Vac 1A
Min.1mA at 5 Vdc
Resistive load
Min permissive load