Input Voltage AC |
115-230 V AC |
Output Voltage DC | 5 V DC |
Output Current | 6A |
Input Data | |
Nominal Input Voltage (2 x Vac) Manual select Input from 115 to 230 |
115 – 230 Vac |
Input Voltage Range (Vac) | 90 - 264 |
Inrush Current (Vn and In Load) I 2t | ≤ 7A ≤5msec. |
Frequency | 47 – 63 Hz ±6% |
Input Current (115 – 230 Vac) | 1 - 0.7 A |
Internal Fuse | T 4 A |
External Fuse (recommended) | 6 A (MCBcurve B) |
Output Data | |
Output Voltage (Vn) Factory Setting ±3% | 12 Vdc |
Adjustment range (Vadj) | 10 – 15.5 Vdc |
Start up with Strong Load (capacitive load) | ≤50.000µ F |
Turn-On delay after applying mains voltage | 1.5 sec. (max) |
Continuous Current at 12 V 40°C (In) | 4 A (115) 6 A (230) |
Continuous Current at 12 V 50°C (In) | 3 A (115) 5 A (230) |
Power Boost Current at 12 V 50°C (In) | 7 A up to 3 min. |
Power Boost Current at 15 Vdc 50°C(In) | 6 A up to 3 min. |
Current max. Overload ≅ 4Vdc (permanent) | Imax=In50°C x(1.8 -2.2) |
Current max. Overload | Imax=In50°C x(1.8 -2.2) |
Max current Short Circuit (Icc) | 10 A |
Hold-up Time ( min. Vac) 12Vdc 5A | T yp. 20 msec |
Residual Ripple | ≤80 mVpp |
Efficiency | ≥ 88 % |
Over temperature Protection | Yes. Shut-down output and automatic restart. |
Short-circuit protection | Yes, Continuous Mode |
Dissipation power load max (W) | 6 |
Over Load protection | Yes, Continuous Mode |
Over Voltage Output protection | Yes |
Parallel connection | Yes |
Ct